How Long Will a Power Station Run a CPAP?
By Hicham M. · Updated October 11, 2026 · How we calculate
A CPAP is one of the easiest things to run on a battery. We plan on 30 W for a CPAP with the humidifier off, which over an 8-hour night is about 240 Wh. At that rate a 1,000 Wh power station covers about 3.5 nights. Switch on the heated humidifier and tube and plan on 60 W or more, which halves it at least.
30 W sits in the middle of what’s published. General wattage charts list 30–60 W for a CPAP without heat, ResMed’s user guides list 53–56 W “typical”, and ResMed’s own battery test works out to about 7 W at a low pressure. Your pressure setting and machine decide where you land.
Runtime by power station
Nonstop runtime for one CPAP at 30 W average, with 85% inverter efficiency. Models that can't supply its running or starting power are listed separately below.
| Power station | Battery | Runtime | Bar |
|---|---|---|---|
| Jackery Explorer 5000 Plus | 5,040 Wh | 5.9 days | |
| EcoFlow DELTA Pro 3 | 4,096 Wh | 4.8 days | |
| Goal Zero Yeti PRO 4000 | 3,994 Wh | 4.7 days | |
| Anker SOLIX F3800 | 3,840 Wh | 4.5 days | |
| Anker SOLIX F3800 Plus | 3,840 Wh | 4.5 days | |
| EcoFlow DELTA Pro Older | 3,600 Wh | 4.2 days | |
| Anker SOLIX F3000 | 3,072 Wh | 3.6 days | |
| BLUETTI Elite 300 | 3,014 Wh | 3.6 days | |
| BLUETTI Apex 300 | 2,765 Wh | 3.3 days | |
| BLUETTI Elite 200 V2 | 2,074 Wh | 2.4 days |
Show the other 44 models that can run it
| Power station | Battery | Runtime | Bar |
|---|---|---|---|
| EcoFlow DELTA 3 Max | 2,048 Wh | 2.4 days | |
| EcoFlow DELTA 3 Max Plus | 2,048 Wh | 2.4 days | |
| EcoFlow DELTA 2 Max Older | 2,048 Wh | 2.4 days | |
| BLUETTI AC200L | 2,048 Wh | 2.4 days | |
| BLUETTI AC200MAX Older | 2,048 Wh | 2.4 days | |
| Anker SOLIX C2000 Gen 2 | 2,048 Wh | 2.4 days | |
| Anker SOLIX F2000 (767) Older | 2,048 Wh | 2.4 days | |
| DJI Power 2000 | 2,048 Wh | 2.4 days | |
| Jackery Explorer 2000 v2 | 2,042 Wh | 2.4 days | |
| Jackery Explorer 2000 Plus Older | 2,042 Wh | 2.4 days | |
| BLUETTI AC200P Older | 2,000 Wh | 2.4 days | |
| Jackery Explorer 1500 v2 | 1,536 Wh | 44 hours | |
| Jackery Explorer 1500 Ultra | 1,536 Wh | 44 hours | |
| Goal Zero Yeti 1500X Older | 1,516 Wh | 43 hours | |
| Goal Zero Yeti 1500 | 1,505 Wh | 43 hours | |
| Jackery Explorer 1000 Plus | 1,264 Wh | 36 hours | |
| Anker SOLIX F1200 (757) Older | 1,229 Wh | 35 hours | |
| BLUETTI AC180 | 1,152 Wh | 33 hours | |
| Jackery Explorer 1000 v2 | 1,070 Wh | 30 hours | |
| Anker SOLIX C1000 | 1,056 Wh | 30 hours | |
| EcoFlow DELTA 3 | 1,024 Wh | 29 hours | |
| EcoFlow DELTA 3 Plus | 1,024 Wh | 29 hours | |
| EcoFlow DELTA 2 Older | 1,024 Wh | 29 hours | |
| BLUETTI Elite 100 V2 | 1,024 Wh | 29 hours | |
| Anker SOLIX C1000 Gen 2 | 1,024 Wh | 29 hours | |
| DJI Power 1000 | 1,024 Wh | 29 hours | |
| Jackery Explorer 1000 Pro Older | 1,002 Wh | 28 hours | |
| Jackery Explorer 1000 Older | 1,002 Wh | 28 hours | |
| Goal Zero Yeti 1000 | 998 Wh | 28 hours | |
| EcoFlow RIVER 2 Pro Older | 768 Wh | 22 hours | |
| Anker SOLIX C800 Plus | 768 Wh | 22 hours | |
| BLUETTI EB70S Older | 716 Wh | 20 hours | |
| Goal Zero Yeti 700 | 677 Wh | 19 hours | |
| Jackery Explorer 500 Older | 518 Wh | 15 hours | |
| EcoFlow RIVER 2 Max Older | 512 Wh | 15 hours | |
| DJI Power 500 | 512 Wh | 15 hours | |
| Jackery Explorer 300 | 293 Wh | 8.3 hours | |
| Jackery Explorer 300 v2 | 288 Wh | 8.2 hours | |
| Anker SOLIX C300 | 288 Wh | 8.2 hours | |
| EcoFlow RIVER 3 Plus | 286 Wh | 8.1 hours | |
| BLUETTI EB3A Older | 269 Wh | 7.6 hours | |
| Jackery Explorer 240 v2 | 256 Wh | 7.3 hours | |
| EcoFlow RIVER 3 | 245 Wh | 6.9 hours | |
| Jackery Explorer 240 Older | 240 Wh | 6.8 hours |
We may earn a commission if you buy through these links. It never changes our numbers, and every model in our database is included whether or not it pays us. Learn more.
What the machine makers publish
| Machine | Power supply | Published consumption |
|---|---|---|
| ResMed AirSense 11 | 65 W | 56.1 W typical, 73.2 W peak |
| ResMed AirSense 10 | 90 W | 53 W typical, 104 W peak |
| ResMed AirMini (travel) | 24 V, 0.83 A | 6.3 W typical, 27 W peak |
| Philips DreamStation 2 | 80 W needed for humidification | Not published |
The “typical” numbers in ResMed’s user guides don’t say which settings they assume, so read them as an upper bound with the humidifier working rather than what your machine draws every night.
What heated humidification costs you
ResMed tested an AirSense 10 on its own 97 Wh Power Station II battery:
| Settings | Run time on 97 Wh | Works out to |
|---|---|---|
| 10 cm H2O, no leak, humidifier and heated tube off | 14.3 hours | about 7 W |
| 20 cm H2O, 20 L/min leak, humidity level 1, heated tube on | 3.3 hours | about 30 W |
| Same, humidity level 4 | 3.35 hours | about 29 W |
Pressure and leak also differ between the first row and the others, so this doesn’t isolate the humidifier, and the humidity level barely mattered. Still, heated humidification at a higher pressure cut the runtime by three quarters. ResMed’s manual says to turn the humidifier off on battery “to maximise the life of your battery”, and Philips says the DreamStation 2 battery doesn’t support humidification at all.
Source: ResMed battery and device compatibility list (2015), hosted by a retailer; “works out to” is our division of 97 Wh by the run time.
Plan before you need it
The FDA asks anyone using a medical device at home to have a plan for outages, including how long the device lasts on battery and whether you have supplies for at least 3 days. Ask your equipment supplier or doctor; a power station is one part of that plan, not all of it.
Stretching a battery through the night
- Turn off the humidifier and heated tube. ResMed recommends it on battery, and Philips’ battery pack doesn’t support humidification at all.
- Use the maker’s DC cable or converter if there is one. ResMed sells DC/DC converters for the AirSense 10 and AirSense 11, and Philips sells a DC cord for DreamStation 2. Running from the station’s 12 V port skips inverter losses. Use only cords your CPAP’s manufacturer approves.
- On AC, the inverter’s own idle draw matters at loads this small. Add 10–20 W under Settings in the runtime calculator for a cautious estimate.
- A station with UPS or EPS mode can keep the CPAP running when the grid drops at night. Confirm that your machine tolerates the switchover before relying on it.
- Don’t rely on a single battery for any medical device. Talk to your doctor or supplier about a backup plan.
Questions
What size power station do I need for a CPAP?
How many watts does a CPAP use?
Can I use a power station for a CPAP when camping?
Related
- How Long Will a Power Station Run a Refrigerator?
- How Long Will a Power Station Run a Chest Freezer?
- How Long Will a Power Station Run an Oxygen Concentrator?
- Can a Power Station Run a Sump Pump?
- Can a Power Station Run a Window Air Conditioner?
- Can a Power Station Run a Space Heater?
- Full appliance wattage chart
Sources
Wattage figures are typical values from the sources below. Your appliance may differ, so check its label or measure it with a plug-in watt meter.
- championpowerequipment.com/generator-wattage-chart
- resmed.com/en-us/products/cpap/machines/airsense-11
- document.resmed.com/documents/products/machine/airsense-11/user-guide/398181…
- document.resmed.com/en-us/documents/products/machine/airsense-series/user-gu…
- resmed.com.au/hubfs/Resmed-ANZ-2020/AirMini-Device-Fact-Sheet.pdf
- thecpapshop.com/media/wysiwyg/pdfs/battery-device-compatibility-list.pdf
- ap.resmed.com/hubfs/Himalayas - B2C/SG/Sleepcare/PDF/power-station-ii_…
- resmed.com/de-de/dam/documents/products/accessory/air-10-s9-90w-dc-…
- documents.philips.com/assets/Instruction for Use/20211202/7e52e95bb1a343a4a223…
- documents.philips.com/assets/Instruction for Use/20251030/c9c42c8a0ebf4f4d8fdd…
- shop.resmed.com/cpap-spare-parts/airsense-11-converter/p/39231
- fda.gov/media/80782/download